Physics Formulae Electricity Generators in Series-Parallel

Subset – Definition and Properties

Learn to calculate total voltage and current using the generators in series-parallel formula. Ideal for system designers...

What are Generators in Series-Parallel?

Generators in series-parallel configuration combine the benefits of both series and parallel connections by arranging generators in groups (strings) where generators within each string are connected in series, and multiple strings are connected in parallel. This hybrid approach allows system designers to achieve both higher voltage (through series connection within strings) and higher current capacity (through parallel connection of strings) while maintaining reasonable efficiency and control complexity. The configuration is commonly expressed as "mSнP" meaning m generators in series forming n parallel branches. This arrangement is fundamental in applications requiring both high voltage and high current, such as electric vehicle battery packs, large-scale energy storage systems, and power systems where standard generator voltages are insufficient but parallel-only configurations would require excessive current-carrying capacity.

Historical Context

The concept of combining power sources in series-parallel is foundational to electrical engineering. Early battery systems in the 1800s used series-parallel combinations of voltaic cells for telegraph systems. Thomas Edison's lighting systems in the 1880s also employed such arrangements to meet different voltage and current requirements. This principle was crucial for early electric vehicles, submarine battery banks during the World Wars, and later adapted for space applications in the 1960s for solar panel arrays. The modern resurgence in electric vehicles and grid-scale energy storage has made the analysis of complex series-parallel systems more critical than ever.

Physical Properties

A series-parallel arrangement of generators results in key electrical properties like total voltage, current, and power, which are determined by the characteristics of individual generators and their specific configuration. These properties are governed by fundamental conservation laws.

PropertyDetails
Scalar/Vector NatureThe primary outputs, such as Electromotive Force (EMF), terminal voltage, and current, are treated as scalar quantities in circuit analysis.
SI Units<ul><li>Voltage (EMF): Volt (V)</li><li>Current: Ampere (A)</li><li>Internal Resistance: Ohm (Ω)</li><li>Power: Watt (W)</li></ul>
MagnitudeThe total EMF is equal to the net EMF of one series string. The total current is the sum of the currents from each parallel string. The total internal resistance depends on the number of generators per string (n) and the number of strings (m).
Governing PrinciplesThe configuration is analyzed using Kirchhoff's Laws. The voltage across each parallel string is the same (Kirchhoff's Voltage Law). The total current leaving the combination is the sum of currents from each string (Kirchhoff's Current Law).
Conservation Laws<strong>Conservation of Energy:</strong> The total electrical power generated by the combination equals the sum of the power delivered to the external load and the power dissipated as heat within the internal resistances of the generators.
Dimensional Formula<ul><li>Voltage (V): M L<sup>2</sup> T<sup>-3</sup> I<sup>-1</sup></li><li>Current (I): I</li><li>Resistance (Ω): M L<sup>2</sup> T<sup>-3</sup> I<sup>-2</sup></li></ul>
📐

Diagram & Visualization

+ - Load m n branches
A series-parallel circuit with 'n' parallel branches, each having 'm' generators in series.
📏

Key Formulas

\[ \xi_{eq} = m \xi \]
Equivalent EMF of m generators in series
\[ R_{series} = m \cdot R_{individual} \]
Total resistance of a single series string
\[ R_{eq} = \frac{R_{series}}{n} = \frac{m \cdot R_{individual}}{n} \]
Total equivalent resistance of n parallel strings
\[ I_{total} = n \cdot I_{string} \]
Total current capability from n parallel strings
\[ V_{terminal} = \xi_{eq} - I_{total} \cdot R_{eq} \]
Terminal voltage under load
\[ P_{total} = V_{terminal} \cdot I_{total} \]
Total power delivered to the load
🔣

Variables and Symbols

SymbolQuantitySI UnitDescription
\(m\)Series CountunitlessNumber of generators connected in series within a single branch or string.
\(n\)Parallel CountunitlessNumber of parallel branches or strings connected together.
\(\xi\)Electromotive Force (EMF)Volt (V)The open-circuit voltage of a single, individual generator.
\(\xi_{eq}\)Equivalent EMFVolt (V)The total effective EMF of the entire series-parallel system.
\(R_{individual}\)Internal ResistanceOhm (Ω)The internal electrical resistance of a single generator.
\(R_{eq}\)Equivalent ResistanceOhm (Ω)The total effective internal resistance of the entire system.
\(I_{total}\)Total CurrentAmpere (A)The total current flowing from the system to the external load.
\(I_{string}\)String CurrentAmpere (A)The current flowing through a single series string. Limited by the lowest-capacity generator in the string.
\(V_{terminal}\)Terminal VoltageVolt (V)The actual voltage measured across the output terminals of the system when under load.
\(P_{total}\)Total PowerWatt (W)The total power delivered by the system to the external circuit.
📐

Derivation of Equivalent Circuit Parameters

The equivalent circuit for a series-parallel generator network can be derived by first analyzing a single series string and then combining multiple strings in parallel.

Step 1: Analyze a single series string

Consider a string with \(m\) identical generators, each with EMF \(\xi_{individual}\) and internal resistance \(R_{individual}\). When connected in series, their EMFs and resistances add up according to Kirchhoff's Voltage Law.

\[ \xi_{string} = \sum_{i=1}^{m} \xi_i = m \cdot \xi_{individual} \]
Total EMF of one series string
\[ R_{string} = \sum_{i=1}^{m} R_i = m \cdot R_{individual} \]
Total internal resistance of one series string

The maximum current that can be drawn from the string is limited by the capacity of a single generator, \(I_{string,max} = I_{individual,max}\).

Step 2: Combine n strings in parallel

Now, consider \(n\) identical strings connected in parallel. For parallel connections, the voltage across each branch is the same. Therefore, the equivalent EMF of the system is equal to the EMF of a single string.

\[ \xi_{eq} = \xi_{system} = \xi_{string} = m \cdot \xi_{individual} \]
Equivalent EMF of the parallel system

The total current capability is the sum of the currents from each parallel branch, according to Kirchhoff's Current Law.

\[ I_{total,max} = \sum_{j=1}^{n} I_{string,max} = n \cdot I_{individual,max} \]
Total current capability

The equivalent resistance for \(n\) identical resistors in parallel is found by the reciprocal formula.

\[ \frac{1}{R_{eq}} = \sum_{j=1}^{n} \frac{1}{R_{string}} = n \cdot \frac{1}{R_{string}} = \frac{n}{m \cdot R_{individual}} \]
Reciprocal of equivalent resistance

Inverting this gives the final expression for the equivalent resistance.

\[ R_{eq} = \frac{m \cdot R_{individual}}{n} \]
Equivalent internal resistance of the system

Step 3: Analyze the full circuit under load

The entire system behaves as a single equivalent generator with EMF \(\xi_{eq}\) and internal resistance \(R_{eq}\). When connected to an external load \(R_{load}\), the total current \(I_{total}\) is given by Ohm's Law for the complete circuit.

\[ I_{total} = \frac{\xi_{eq}}{R_{eq} + R_{load}} \]

The terminal voltage across the load is the total EMF minus the voltage drop across the equivalent internal resistance.

\[ V_{terminal} = I_{total} \cdot R_{load} = \xi_{eq} - I_{total} \cdot R_{eq} \]
📚

Types & Special Cases

The behavior and efficiency of a series-parallel generator bank depend heavily on the uniformity of the individual generators and the symmetry of the configuration. Different cases arise based on whether the components are identical.

Type / CaseDescriptionWhen to Use
Symmetrical ConfigurationAll generators have identical EMF and internal resistance, and each parallel string contains the same number of generators. This is the ideal and most efficient setup.Standard applications requiring both high voltage and high current, such as in battery packs for electric vehicles, solar arrays, or large-scale uninterruptible power supplies (UPS).
Asymmetrical ConfigurationGenerators or strings are non-identical (e.g., different EMFs, internal resistances, or number of cells per string). This leads to inefficient power delivery and potentially damaging circulating currents between strings.This configuration is generally avoided in design. It may occur unintentionally due to component failure or degradation over time, and it requires careful analysis to prevent system damage.
Maximum Power TransferA specific condition where the total internal resistance of the generator array is matched to the resistance of the external load. This arrangement maximizes the power delivered to the load, but at only 50% efficiency.Used in applications where delivering maximum power is more critical than efficiency, such as in radio transmitter antenna coupling or for starting high-torque motors.
Open/Short Circuit ConditionsLimiting cases used for analysis. In an open circuit, the load resistance is infinite, current is zero, and terminal voltage is maximum (equal to the total EMF). In a short circuit, load resistance is zero, voltage collapses, and current is maximum.Primarily used for testing and characterizing the generator bank's performance limits, such as measuring the open-circuit voltage and short-circuit current.
🔢

Worked Example (Numerical)

A power system is built using identical generators, each with an EMF (\(\xi\)) of 12 V and an internal resistance (\(R\)) of 0.5 Ω. The system is configured with 3 generators in series per string (\(m=3\)), and 4 such strings in parallel (\(n=4\)). If this system is connected to an external load resistor of 10 Ω, what are the system's equivalent EMF, equivalent internal resistance, total current, and terminal voltage?
  1. <strong>Step 1: Calculate the parameters of a single series string.</strong><br>The EMF of one string is \(\xi_{string} = m \cdot \xi = 3 \cdot 12\text{ V} = 36\text{ V}\).<br>The resistance of one string is \(R_{string} = m \cdot R = 3 \cdot 0.5\text{ Ω} = 1.5\text{ Ω}\).
  2. <strong>Step 2: Calculate the equivalent parameters for the entire system.</strong><br>The equivalent EMF is the same as a single string's EMF: \(\xi_{eq} = \xi_{string} = 36\text{ V}\).<br>The equivalent resistance is the string resistance divided by the number of parallel strings: \(R_{eq} = \frac{R_{string}}{n} = \frac{1.5\text{ Ω}}{4} = 0.375\text{ Ω}\).
  3. <strong>Step 3: Calculate the total current flowing through the load.</strong><br>Using Ohm's law for the entire circuit (equivalent source plus external load):<br>\[I_{total} = \frac{\xi_{eq}}{R_{eq} + R_{load}} = \frac{36\text{ V}}{0.375\text{ Ω} + 10\text{ Ω}} = \frac{36}{10.375} \approx 3.47\text{ A}\]
  4. <strong>Step 4: Calculate the terminal voltage across the load.</strong><br>The terminal voltage is the voltage drop across the external resistor, or the equivalent EMF minus the internal voltage drop.<br>\[V_{terminal} = \xi_{eq} - I_{total} \cdot R_{eq} = 36\text{ V} - (3.47\text{ A} \cdot 0.375\text{ Ω}) = 36 - 1.30 = 34.7\text{ V}\]<br>Alternatively: \(V_{terminal} = I_{total} \cdot R_{load} = 3.47\text{ A} \cdot 10\text{ Ω} = 34.7\text{ V}\).
The system has an equivalent EMF of 36 V and an equivalent internal resistance of 0.375 Ω. When connected to a 10 Ω load, it supplies a total current of approximately 3.47 A, resulting in a terminal voltage of 34.7 V.
🧮

Try It

🔬

Applications in Science and Technology

Electric Vehicle (EV) Battery Packs: Modern EVs use thousands of individual battery cells. They are arranged in a series-parallel configuration (e.g., 96s4p) to achieve high system voltages (400V or 800V) for efficiency and power, combined with high capacity (amper-hours) for long range.

Grid-Scale Energy Storage Systems (ESS): Utility-scale batteries that stabilize the power grid are built from modules of cells in series-parallel. This allows them to match grid voltage requirements while storing and delivering massive amounts of energy (megawatt-hours).

Solar Power Systems: Photovoltaic panels are connected in series strings to build up voltage to a level suitable for the inverter. Multiple strings are then connected in parallel to increase the total current and power output of the array.

Uninterruptible Power Supplies (UPS): Large data centers and hospitals rely on UPS systems with extensive battery banks. These banks use series-parallel connections to provide the required backup voltage and current for a specified duration during a power outage.

Marine and Aerospace Power Systems: Electric propulsion systems on ships and the power systems in satellites and aircraft use series-parallel configurations to provide reliable, redundant, and high-power electrical sources tailored to specific voltage and current needs.

🌍

Real-World Examples

Design a battery pack for an electric vehicle using lithium-ion cells in a series-parallel configuration. The requirements are a 400V nominal voltage, 200 kWh capacity, and 500 kW peak power. Each available cell has the following specifications: 3.7V, 100 Ah, and 0.002 Ω internal resistance.
  1. <p><strong>Part (a): Configuration determination</strong></p><p><strong>Series requirement for voltage:</strong></p><div class="math-formula">\[ m = \frac{V_{target}}{V_{cell}} = \frac{400}{3.7} = 108.1 \text{ cells} \]</div><p>Use m = 108 cells in series per string (399.6V)</p><p><strong>Parallel requirement for capacity:</strong></p><p>Energy per string: E_string = 399.6V × 100 Ah = 39.96 kWh</p><div class="math-formula">\[ n = \frac{E_{target}}{E_{string}} = \frac{200}{39.96} = 5.01 \text{ strings} \]</div><p>Use n = 5 parallel strings</p><p>Final configuration: 108S5P = 540 total cells</p><p><strong>Actual specifications achieved:</strong></p><div class="math-formula">\[ V_{nominal} = 108 \times 3.7 = 399.6 \text{ V} \]</div><div class="math-formula">\[ C_{total} = 5 \times 100 = 500 \text{ Ah} \]</div><div class="math-formula">\[ E_{total} = 399.6 \times 500 = 199.8 \text{ kWh} \]</div>
  2. <p><strong>Part (b): Power capability and internal resistance</strong></p><p><strong>Internal resistance calculation:</strong></p><div class="math-formula">\[ R_{string} = 108 \times 0.002 = 0.216 \text{ Ω per string} \]</div><div class="math-formula">\[ R_{pack} = \frac{0.216}{5} = 0.0432 \text{ Ω total} \]</div><p><strong>Peak power capability:</strong></p><p>Maximum continuous current per cell: 3C = 300A</p><p>Peak current capability: I_peak = 5 × 300 = 1500A</p><div class="math-formula">\[ V_{terminal,peak} = 399.6 - 1500 \times 0.0432 = 334.8 \text{ V} \]</div><div class="math-formula">\[ P_{peak} = 334.8 \times 1500 = 502.2 \text{ kW} \]</div><p>Meets 500 kW requirement with small margin</p><p><strong>Efficiency at peak power:</strong></p><p>Power loss: P_loss = I² × R = 1500² × 0.0432 = 97.2 kW</p><div class="math-formula">\[ \eta_{peak} = \frac{502.2}{502.2 + 97.2} = 83.8\% \]</div>
  3. <p><strong>Part (c): Alternative configuration analysis</strong></p><p><strong>Option 1: 54S10P configuration</strong></p><p>Voltage: 54 × 3.7V = 199.8V (half voltage)</p><p>Internal resistance: (54 × 0.002Ω) / 10 = 0.0108Ω</p><div class="math-formula">\[ P_{max} = (199.8 - 1500 \times 0.0108) \times 1500 = 275.4 \text{ kW} \]</div><p>Insufficient power - only 55% of requirement</p><p><strong>Option 2: 216S3P configuration</strong></p><p>Voltage: 216 × 3.7V = 799.2V (double voltage)</p><p>Current limited by 3 parallel strings: I_max = 3 x 300A = 900A</p><p>Internal resistance: (216 × 0.002Ω) / 3 = 0.144Ω</p><div class="math-formula">\[ P_{max} = (799.2 - 900 \times 0.144) \times 900 = 602.6 \text{ kW} \]</div><p>Exceeds power requirement but uses 648 cells vs 540, increasing cost and weight.</p>
The optimal configuration is 108S5P (108 cells in series, 5 strings in parallel) using 540 cells total. This provides 399.6V, 199.8 kWh, and a peak power of 502 kW. The total internal resistance is 0.0432Ω, with an efficiency of 83.8% at peak power. Alternative configurations are either underpowered (54S10P) or oversized and more expensive (216S3P).
A small hydroelectric power station needs to be configured using 8 available identical generators, each rated at 2.5 MW, 6.6 kV. The required output to the grid is 13.2 kV at 15 MW total power. Determine the optimal series-parallel configuration and analyze its performance and fault tolerance.
  1. <p><strong>Part (a): Configuration determination</strong></p><p><strong>Voltage requirement analysis:</strong></p><div class="math-formula">\[ m = \frac{V_{target}}{V_{generator}} = \frac{13.2 \text{ kV}}{6.6 \text{ kV}} = 2 \text{ generators in series} \]</div><p>To achieve 13.2 kV, 2 generators must be connected in series per string.</p><p><strong>Power requirement analysis:</strong></p><p>Power per 2-generator series string: P_string = 2 × 2.5 MW = 5 MW</p><div class="math-formula">\[ n = \frac{P_{target}}{P_{string}} = \frac{15 \text{ MW}}{5 \text{ MW}} = 3 \text{ parallel strings} \]</div><p>To achieve 15 MW, 3 such strings must be connected in parallel.</p><p><strong>Final configuration: 2S3P</strong>. This uses 2x3 = 6 generators, leaving 2 as spares.</p>
  2. <p><strong>Part (b): System performance analysis</strong></p><p>Assume 5% voltage regulation per generator, which corresponds to an internal resistance of R_gen = (0.05 × 6.6 kV) / (2.5 MW / 6.6 kV) ≈ 0.87 Ω.</p><p>Resistance per string: \(R_{string} = 2 \times 0.87 = 1.74 \text{ Ω}\)</p><p>Total system equivalent resistance: \(R_{system} = \frac{1.74}{3} = 0.58 \text{ Ω}\)</p><p>Total system current: \(I_{total} = P/V = 15\text{MW} / 13.2\text{kV} = 1136\text{ A}\)</p><p>Terminal voltage under full load: \(V_{terminal} = 13.2 \text{ kV} - (1136 \text{ A} \times 0.58 \text{ Ω}) = 12.54 \text{ kV}\)</p><p>Voltage regulation is (13.2 - 12.54) / 13.2 = 5%, which is acceptable.</p>
  3. <p><strong>Part (c): Fault tolerance analysis</strong></p><p>If a single generator fails, the entire 2-generator string it belongs to must be taken offline. The system is reduced to a 2S2P configuration.</p><p>Remaining power capacity = 2 strings × 5 MW/string = 10 MW.</p><p>This is a 33% reduction in capacity (from 15 MW to 10 MW). The system can continue to operate, but the load must be shed to 10 MW to prevent overloading the remaining generators.</p><p>An alternative 2S4P design using all 8 generators would provide 20 MW capacity, allowing the system to still deliver the required 15 MW even after losing one string (N-1 redundancy).</p>
A 2S3P configuration meets the 13.2 kV, 15 MW target using 6 of the 8 available generators. The system performs with acceptable 5% voltage regulation. However, the failure of a single generator results in a 33% loss of capacity. For higher reliability, a 2S4P configuration using all 8 generators would be recommended to provide N-1 redundancy.
💡

Where It Appears in Daily Life

Battery Pack
Electric Car Battery
An electric car's battery pack connects thousands of cells in series-parallel. Series strings increase voltage, while parallel strings increase capacity for longer range.
Inverter
Rooftop Solar Array
Solar installations wire panels into series strings for high voltage. Multiple strings are then connected in parallel to increase the total current and power output.
Cells Inside
Portable Power Station
Portable power stations use series-parallel cell configurations to balance the high voltage and current demands of their outlets and ports from a compact battery pack.

Electric Car Battery Packs

The large battery pack under an electric car is not one single battery. It's an array of hundreds or thousands of smaller cylindrical or pouch cells. To get the high voltage (e.g., 400 Volts) needed to run the motor efficiently, many cells are connected in series. To get the high capacity needed for long driving range, multiple of these series 'strings' are connected in parallel.

Rooftop Solar Installations

Solar panels on a roof are arranged in a similar way. To generate a high enough DC voltage for the inverter to work efficiently, several panels are wired together in a series string. If the roof is large, multiple strings are installed and then connected in parallel before the wiring runs to the inverter, increasing the total current and power generated.

Portable Power Stations and Tool Batteries

High-power cordless tools (like drills or saws) and portable power stations for camping use battery packs with cells in a series-parallel configuration. This allows them to deliver the high voltage and current needed for powerful motors from a compact package, balancing performance with battery life.

⚠️

Limitations and Assumptions

⚠️ The formulas assume all generators (or cells) are perfectly identical. In reality, small variations in voltage, capacity, and internal resistance exist. These imbalances can cause uneven current sharing between parallel strings and lead to over-charging or over-discharging of some cells, reducing the system's lifespan and performance.
⚠️ The analysis assumes static conditions. Internal resistance and voltage change with temperature, age, and state of charge. A hot, fully charged battery pack will behave differently than a cold, nearly empty one. These dynamic effects are not captured by the basic equations.
💡 The calculations ignore parasitic resistance from wiring, busbars, and connectors. In high-current systems, these resistances can cause significant voltage drops and power loss (as heat), reducing overall system efficiency.

Common Mistakes

⚠️ Confusing Series and Parallel Rules: A common error is incorrectly applying the rules for combining resistance and voltage. Remember: in series, voltages and resistances add directly (\(\xi_{eq} = m\xi, R_{string} = mR\)). In parallel, the equivalent resistance is \(R_{eq} = R_{string}/n\) and the voltage remains the same.
⚠️ Misunderstanding Fault Modes: Students often forget that the failure of a single component in a series string (e.g., an open circuit) disables the entire string. The system's fault tolerance comes from having multiple parallel strings, not from the series connections themselves.
⚠️ Ignoring the Current Bottleneck: In a series string, the maximum current is limited by the weakest cell or generator in that string. You cannot draw more current than the lowest-rated component can handle, regardless of how many parallel strings are added.
⚖️

Units and Dimensional Analysis

Understanding the units and dimensions of the quantities involved is crucial for verifying the correctness of the formulas.

QuantitySI UnitDimensional Formula
Voltage / EMF (\(\xi, V\))Volt (V)\([M L^2 T^{-3} I^{-1}]\)
Current (\(I\))Ampere (A)\([I]\)
Resistance (\(R\))Ohm (Ω)\([M L^2 T^{-3} I^{-2}]\)
Power (\(P\))Watt (W)\([M L^2 T^{-3}]\)
Energy (\(E\))Joule (J)\([M L^2 T^{-2}]\)

Dimensional Check (Terminal Voltage): Let's check the dimensions of \(V_{terminal} = \xi_{eq} - I_{total} R_{eq}\).
Dimension of \(\xi_{eq}\) is \([M L^2 T^{-3} I^{-1}]\).
Dimension of \(I_{total} R_{eq}\) is \([I] \cdot [M L^2 T^{-3} I^{-2}] = [M L^2 T^{-3} I^{-1}]\).
Since both terms have the dimensions of voltage, the equation is dimensionally consistent.

🎯

Study Strategy

1 🧠 Grasp the Fundamentals
  • Thoroughly read the DEFINITION section to understand why series connections boost voltage and parallel connections increase current capacity.
  • Draw two diagrams: one for 'm' generators in series and another for 'n' generators in parallel. Label the total EMF and resistance for each.
  • Visualize the hybrid 'string' concept: a group of series-connected generators that acts as a single unit.
  • List and define each key variable from the formula: ξ (EMF of one generator), R (internal resistance of one), m (number in series), and n (number of parallel strings).
2 📝 Commit the Formula to Memory
  • Break down the formula for equivalent EMF: ξ_eq = mξ. Understand that total voltage is set by a single string.
  • Analyze the equivalent internal resistance: R_eq = mR/n. See how it combines series addition (mR) with parallel division (/n).
  • Write the full formula for current (I = mξ / (R_ext + mR/n)) from memory five times without looking.
  • Create flashcards for each component: equivalent EMF, equivalent resistance, and total current, with the formula on the back.
3 ✍️ Practice with Problems
  • Solve a 'Worked Example' problem without looking at the solution. First calculate ξ_eq, then R_eq, and finally the total current.
  • Review the COMMON MISTAKES section. Create your own tricky problem that tests the correct application of series vs. parallel rules.
  • Solve a problem based on a fault mode mentioned in COMMON MISTAKES, like what happens if one generator in a string fails (open circuit).
  • Invent new problems by changing 'm' and 'n'. Calculate the output for a 4s2p vs. a 2s4p configuration using the same generators.
4 🌍 Connect to Real-World Physics
  • Study the APPLICATIONS section on EV battery packs. Explain why a 96s4p configuration is used to achieve both high voltage and long range.
  • Research the Grid-Scale Energy Storage Systems from the APPLICATIONS section. Find a real-world example and its voltage/capacity specifications.
  • Sketch a series-parallel battery system for a hypothetical solar-powered cabin, justifying your choice of 'm' and 'n'.
  • Explain how the parallel component (n > 1) of the design provides redundancy, a key benefit in real-world systems like spacecraft power.
Master the series-parallel configuration by first separating the series and parallel rules, then combining them to solve practical, real-world problems.